1.5 ATA Medical Oxygen Therapy Chamber for Enhanced Recovery Potential

Product Details
Customization: Available
Certification: CE, ISO13485
LCD Display: With LCD Display
Still deciding? Get samples of US$ 12000/Piece
Request Sample
Manufacturer/Factory, Trading Company
Diamond Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Fast Delivery
The supplier can deliver the goods within 15 days
Full Customization
The supplier provides full customization services
OEM Services
The supplier provides OEM services for popular brands
to see all verified strength labels (13)
  • 1.5 ATA Medical Oxygen Therapy Chamber for Enhanced Recovery Potential
  • 1.5 ATA Medical Oxygen Therapy Chamber for Enhanced Recovery Potential
  • 1.5 ATA Medical Oxygen Therapy Chamber for Enhanced Recovery Potential
  • 1.5 ATA Medical Oxygen Therapy Chamber for Enhanced Recovery Potential
  • 1.5 ATA Medical Oxygen Therapy Chamber for Enhanced Recovery Potential
  • 1.5 ATA Medical Oxygen Therapy Chamber for Enhanced Recovery Potential
Find Similar Products
  • Overview
  • Product Parameters
  • Product Details
  • Detailed Photos
  • Application Field
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
LC-R1
Group
Adult
Properties
Rehabilitation Therapy Supplies
Feature
Portable/Foldable/Easy Operation/Safe
Pressure
1.3 ATA (4 Psi) / 1.4 ATA (6 Psi) / 1.5 ATA (8 Psi
Oxygen Purity
≥90%
Application
Medical/SPA/Gym/Home/Health Care Physiotherapy
Volatage
110V/220V/240V
Warranty
1 Year
Flow Rate
10L/Min
Product Name
Hard 3ATA Hyperbaric-Oxygen-Chamber with Concentra
Cabin Specifications
850X2000mm
Single Gross Weight
850kg
Chamber Material
Reinforced Composite Materials
Oxygen Flow
10L-30L/Minute Adjustable
Rated Capacity
1-20 Person / Customized Multi Person
Transport Package
Wooden Case
Specification
Max L1900/2000/2100/2200mm*D700/D800/D850mm
Trademark
LABS
Origin
China
Production Capacity
2000

Product Description

1.5 ATA Medical Oxygen Therapy Chamber for Enhanced Recovery Potential
Who benefits from hyperbaric oxygen therapy?
In today's fast-paced world, modern lifestyles often confine people indoors for extended periods. Coupled with outdoor environmental
pollution, this can significantly reduce oxygen levels in the body. High-pressure oxygen therapy effectively helps
a wide range of individuals maintain optimal health and overall wellness.
For instance, white-collar workers, students, and other mentally demanding professionals, as well as
sports and fitness enthusiasts, require substantial oxygen intake. Without additional oxygen supplementation, they may suffer
from subhealth symptoms such as dizziness, persistent fatigue, insomnia at night, and drowsiness during the day.
due to a lack of extra oxygen supplementation.
As individuals age, the ability to absorb oxygen molecules decreases. Micro high-pressure oxygen therapy
can be utilized to replenish oxygen levels, thus accelerating post-surgery recovery.
Additionally, this therapy aids in reducing inflammation and speeding up the healing of wounds.
Product Parameters
1.5 ATA Medical Oxygen Therapy Chamber for Enhanced Recovery Potential

 

Product Parameters
1.5 ATA Medical Oxygen Therapy Chamber for Enhanced Recovery Potential1.5 ATA Medical Oxygen Therapy Chamber for Enhanced Recovery Potential1.5 ATA Medical Oxygen Therapy Chamber for Enhanced Recovery Potential1.5 ATA Medical Oxygen Therapy Chamber for Enhanced Recovery Potential
Product name
High Performance Hyperbaric-Oxygen-Chamber oxygen capsule 2 ata camara hiperbaric oxigeno HBOT chamber
Application
Hosipital,Home,Health Center,Medical,Gym
Control System
In-cabin touch screen UI(support multi-langue)
Chamber Material
304 stainless steel + interior soft decoration+ environmental spray paint
Diffuse oxygen concentration
≤30%
Working pressure in the cabin
100-200KPa adjustable
Working noise
<30db
Safety Facilities
Manual safety valve, automatic safety valve
Temperature in the cabin
Ambient temperature +3°C (without air conditioner)
About Oxygen System
Model: uMR O8+
Size: H902.7*L520*W590mm
Control System: Touch screen control(10 inch)+control panel
Power Supply: AC 100V-240V 50/60Hz
Power:750W
Oxygen Pipe Diameter: 8 mm
Air Pipe Diameter: 12 mm
Oxygen flow: 15L/min
Max airflow: 300 L/min
Max Outlet pressure:200KPA(2ATA)
Oxygen Purity: 96%±3%
Oxygen system: air filter (PSA)
Compressor: Oil-free compressor air delivery system
Noise:≤45db
Appearance:
UI:Real-time pressure display: In-chamber control panel

 

Product Details
1.5 ATA Medical Oxygen Therapy Chamber for Enhanced Recovery Potential1.5 ATA Medical Oxygen Therapy Chamber for Enhanced Recovery Potential1.5 ATA Medical Oxygen Therapy Chamber for Enhanced Recovery Potential1.5 ATA Medical Oxygen Therapy Chamber for Enhanced Recovery Potential1.5 ATA Medical Oxygen Therapy Chamber for Enhanced Recovery Potential

 

Detailed Photos
1.5 ATA Medical Oxygen Therapy Chamber for Enhanced Recovery Potential1.5 ATA Medical Oxygen Therapy Chamber for Enhanced Recovery Potential1.5 ATA Medical Oxygen Therapy Chamber for Enhanced Recovery Potential1.5 ATA Medical Oxygen Therapy Chamber for Enhanced Recovery Potential

 

Application Field

1.5 ATA Medical Oxygen Therapy Chamber for Enhanced Recovery Potential

Company Profile
Zhengzhou Labsnova Technology Co., Ltd. specializes in manufacturing high-quality Oxygen Chambers in China.
Our factory, certified with ISO9001, has been a prominent player in the international trade market since 2012.
With a track record of 12 years
of extensive export experience, our products have a global distribution footprint.
We have developed a comprehensive foreign trade sales system, ensuring every customer enjoys an
exceptional service experience.
Our products feature high-quality components from world-renowned brands, ensuring stability and
uncompromised quality. With an annual production exceeding 5,000 units,
each undergoes rigorous testing
before dispatch, guaranteeing product excellence.
Additionally, we offer
a range of personalized customizations to meet individual customer requirements.
Over the past 12 years, we have provided comprehensive products and services to thousands of
clients worldwide, building a robust portfolio of successful projects.
These accomplishments have equipped us
with strong service capabilities, instilling confidence in our ability to serve our customers effectively.
We aim to be your dependable partner in China, and we look forward to collaborating with you.
We strive to be your reliable partner in China and look forward to building a prosperous collaboration.
We will be your dependable golf cart partner in China, eagerly anticipating our cooperation.
We will be your reliable golf cart partner in China. Looking forward to cooperating with you.
1.5 ATA Medical Oxygen Therapy Chamber for Enhanced Recovery Potential
FAQ

1.Q: The frequency and time of oxygen therapy are recommendedA: Once a day, 60 minutes is recommended, and the time point is not limited.

2.Q: How to choose the pressure value of the third gear?A: For the first use of oxygen chambers, ear pressure will not be adjusted, first use 10kPa,
then slowly pressurize, and finally use 30kPa.

3.Q: The oxygen concentration in the cabin has been maintained at 22%- 23%, while other
companies can achieve up to 26%.
A: The standard stipulates that the oxygen concentr ation cannot exceed 23%,which is a risk of fire.

4.Q: The cabin is hot and stuffy and cannot circulate with the air in the environmentA: The normal cabin temperature will be 3~5.C higher than the room temperature, and the humidity
will be 20% higher than the room.It is more comfortable to use in spring, autumn and winter,it is
recommended to lower the indoor temperature when using itin summer; Other houses also use
diffuse or ducted air intake pressurization, which cannot circulate with the outside air. In response
to the sweltering heat in the cabin, we have innova- tively designed a spray air device to experience
the comfort of a gentle breeze from any angle.

5.Q: What do I need to prepare before use?
A: (1) In order to ensure the comfort of the cabin, it is recom- mended to use it in a room at 20°C. (2) Before entering theoxygen tank, empty the two defeces.
(3) Take off your shirt, tie, glasses, etc. and change into comfort- able cotton clothing

6.Q: The control interface of the oxygen chamber screen keeps beeping after exiting oxygen
therapy, and I don't know how to operate.
A: In order to prevent the suffocation hazard of single use at home, it is reminded to stop the gas
supply after confirming that there is no one in the cabin. Press to stop the air supply, you can exit,
and the buzzer does not sound.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier