Who needs hyperbaric oxygen therapy?
Modern individuals who spend extensive time indoors, combined with exposure to outdoor environmental
pollution, often suffer from oxygen deficiency. Hyperbaric oxygen therapy can help most people maintain their overall health.
through high-pressure oxygen therapy.
For instance, white-collar professionals, students, and other cognitive workers, as well as
sports and fitness enthusiasts, who have high oxygen demands, are susceptible to sub-health
symptoms like dizziness, fatigue, insomnia at night, and daytime drowsiness if
not supplemented with additional oxygen.
As people age, their bodies' ability to absorb oxygen molecules decreases. Micro hyperbaric oxygen therapy can
be utilized to supplement oxygen, thereby accelerating recovery from surgeries and
also aiding in the faster healing of inflammation and wounds.
be used to accelerate inflammation and wound recovery.
Product Parameters
Product name
|
High Performance Hyperbaric-Oxygen-Chamber oxygen capsule 2 ata camara hiperbaric oxigeno HBOT chamber
|
Application
|
Hosipital,Home,Health Center,Medical,Gym
|
Control System
|
In-cabin touch screen UI(support multi-langue)
|
Chamber Material
|
304 stainless steel + interior soft decoration+ environmental spray paint
|
Diffuse oxygen concentration
|
≤30%
|
Working pressure in the cabin
|
100-200KPa adjustable
|
Working noise
|
<30db
|
Safety Facilities
|
Manual safety valve, automatic safety valve
|
Temperature in the cabin
|
Ambient temperature +3°C (without air conditioner)
|
About Oxygen System
|
Model: uMR O8+
Size: H902.7*L520*W590mm
Control System: Touch screen control(10 inch)+control panel
Power Supply: AC 100V-240V 50/60Hz
Power:750W
Oxygen Pipe Diameter: 8 mm
Air Pipe Diameter: 12 mm
Oxygen flow: 15L/min
Max airflow: 300 L/min
Max Outlet pressure:200KPA(2ATA)
Oxygen Purity: 96%±3%
Oxygen system: air filter (PSA)
Compressor: Oil-free compressor air delivery system
Noise:≤45db
Appearance:
UI:Real-time pressure display: In-chamber control panel
|
Product Details
Detailed Photos
Application Field
Company Profile
Zhengzhou Labsnova Technology Co., Ltd is a premier Micro Hyperbaric
Oxygen Chamber manufacturer in China, headquartered in Zhengzhou. Our factory has achieved ISO9001 certification and has been a key player in foreign trade since 2012.
certification and has been engaged in foreign trade business since 2012. With 12 years
of extensive export experience, our products are now sold in numerous countries globally. We
operate a sophisticated and comprehensive foreign trade sales system, ensuring every customer enjoys an excellent service experience.
a good service experience.
Our products are assembled using high-quality, world-renowned brand components to ensure stability and
top-tier quality, boasting an annual output of over 5,000 units. Every unit undergoes rigorous testing
before leaving the factory to guarantee they meet quality standards. Moreover, we offer
a wide range of customizable products tailored to meet individual customer requirements.
Over the past 12 years, we have delivered complete solutions and services to thousands of
clients across various countries globally. The success of these projects has empowered us with
strong service capabilities, making us confident in our ability to serve our customers exceptionally well.
We aim to be your trusted partner in China, and we look forward to a fruitful collaboration with you.
FAQ
1.Q: The frequency and time of oxygen therapy are recommendedA: Once a day, 60 minutes is recommended, and the time point is not limited.
2.Q: How to choose the pressure value of the third gear?A: For the first use of oxygen chambers, ear pressure will not be adjusted, first use 10kPa,
then slowly pressurize, and finally use 30kPa.
3.Q: The oxygen concentration in the cabin has been maintained at 22%- 23%, while other
companies can achieve up to 26%.A: The standard stipulates that the oxygen concentr ation cannot exceed 23%,which is a risk of fire.
4.Q: The cabin is hot and stuffy and cannot circulate with the air in the environmentA: The normal cabin temperature will be 3~5.C higher than the room temperature, and the humidity
will be 20% higher than the room.It is more comfortable to use in spring, autumn and winter,it is
recommended to lower the indoor temperature when using itin summer; Other houses also use
diffuse or ducted air intake pressurization, which cannot circulate with the outside air. In response
to the sweltering heat in the cabin, we have innova- tively designed a spray air device to experience
the comfort of a gentle breeze from any angle.
5.Q: What do I need to prepare before use?
A: (1) In order to ensure the comfort of the cabin, it is recom- mended to use it in a room at 20°C. (2) Before entering theoxygen tank, empty the two defeces.
(3) Take off your shirt, tie, glasses, etc. and change into comfort- able cotton clothing
6.Q: The control interface of the oxygen chamber screen keeps beeping after exiting oxygen
therapy, and I don't know how to operate.A: In order to prevent the suffocation hazard of single use at home, it is reminded to stop the gas
supply after confirming that there is no one in the cabin. Press to stop the air supply, you can exit,
and the buzzer does not sound.